Lincoln LMC 101 Controller for Lubrication The versatile SKF LMC 101 controller operates as a timer or controller on single-line or progressive lubrication systems. Developed for use on off-road and mobile equipment, the LMC 101 also is suitable for many low-voltage, industrial lubrication applications, such as those found in food and beverage, pulp and paper and steel markets. When operating as a controller, the LMC 101 ends the lubrication cycle when a pressure switch, pressure transducer or piston detector is actuated.
Key source specifications include Model 86535; Power Input: 12 or 24 V DC, -20% + 30%; Operating Temperature: -40°F to +150°F (-40°C to 66°C); Enclosure Size: 7.3 x 4.7 x 2.3″ (186 x 120 x 59mm).
Key Features
- Power Input: 12 or 24 V DC, -20% + 30%
- Operating Temperature: -40°F to +150°F (-40°C to 66°C)
- Enclosure Size: 7.3 x 4.7 x 2.3″ (186 x 120 x 59mm)
- Voltage: 12-24 VDC
- Lincoln LMC 101 Controller for Lubrication
- Operates single-line or progressive lubrication systems
Ideal For
Choose this product if you need:
- Replacement, repair, or installation work involving Lubrication
- Electrical systems using the listed 12-24 VDC supply
Not Ideal For
Not ideal for equipment outside the listed Lubrication compatibility, electrical systems that do not use 12-24 VDC, or temperatures outside the listed -40°F to +150°F (-40°C to 66°C) range.
Product Details
Review the product details below to confirm the model / mpn, power input, operating temperature, enclosure size, voltage match your equipment or lubrication system.
Shared Product Details
| Brand | Lincoln Industrial |
| Model / MPN | 86535 |
| Power Input | 12 or 24 V DC, -20% + 30% |
| Enclosure Rating | NEMA 12 |
| Operating Temperature | -40°F to +150°F (-40°C to 66°C) |
| Inputs | 4 |
| Approvals | None |
| Pump Relay Contact | 20 amps at 30 V DC |
| Vent and Alarm Relay Contacts | 2 amps at 30 V DC |
| Enclosure Size | 7.3 x 4.7 x 2.3″ (186 x 120 x 59mm) |
| Mounting Dimensions | 6.75 x 3.5″ (172 x 89mm) |
| Voltage | 12-24 VDC |
| Outputs | 4 |
Additional Product Information
When operating as a controller, the LMC 101 ends the lubrication cycle when a pressure switch, pressure transducer or piston detector is actuated. In the timer mode, the lubrication cycle ends when time has expired.
Designed to meet OEM vibration standards for major construction equipment, the LMC 101 controller can cycle a pneumatically, hydraulically or electrically driven pump in one-to 10 second intervals.
LMC 101 controller features:
- Functions as a timer or controller
- Records history of system operation and fault codes
- Configured using PC software and USB connection
- Controls FlowMaster or high-current pump without external relay
- Uses pressure switch or pressure transducers (1 to 6V or 4 to 20 mA) in controller mode
- LED indicators show power, pump function, low-level fault and system faults
- Manual lubrication cycle activation button
- Data logging includes date and time of alarms, power ups, configuration changes, lubrication count, manual lubrication count, pressure alarm, low levels and pump on-time information
Four Inputs:
- Two pressure switches, pressure transducers or piston detectors
- Remote manual lubrication switch
- Low-level switch
Four Inputs:
- Low-level alarm relay
- System fault relay
- Vent solenoid
Frequently Asked Questions
What does this fit?
The supplied product data identifies it for Lubrication.
What model number should I verify?
Confirm model or manufacturer part number 86535.
What voltage does it use?
The listed operating voltage is 12-24 VDC.